Go to product list

Excellent delivery based on the successful platform oceanus 35

restorer

First class delivery due to the high pushability of the catheter and short deflation rates of the balloon.

Improved trackability due to the unique and flexible strut design:

  • Nested peaks
  • Helicoidal linkage system

The low profile of its design ensures better crossability

Excellent arterial sustainment

Restorer features an outstanding radial force up to 79% higher with less metal.

restorer

Unique design

The unique design of the stent provides a superior adaptability to the vessel wall.

restorer

Lower restenosis

Restorer is designed to minimize the potential risk of restenosis thanks to a technologically innovative manufacturing process.

  • Optimized metal content while keeping an outsanding radial force
  • Ultrasmooth electropolished surface

restorer

 

Restorer is a CoCr stent system with open cell design pre-mounted in a double lumen coaxial balloon catheter (OTW) for percutaneous transluminal angioplasty of peripheral arteries.

The peripheral stent system is indicated for the treatment of de novo or restenotic atherosclerotic lesions in protected peripheral arteries located under the aortic arch, and for palliation of biliary tract malignant stenosis with a nominal diameter ranging from 5 and 10 mm.

The stent design gives restorer the following:

  • Optimal radial force with less metal

  • Superior conformability to the vessel wall

  • Enhanced trackability due to unique strut design featuring nested peaks and helicoidal linkage system

  • Unmatched recoil

  • Low foreshortening

  • Ultrasmooth electropolished surface

 

The platform based on a modified balloon catheter oceanus 35 gives contributes with:

  • Hydrophilic coating for a better trackability

  • Low crossing profile for a higher crossability of severe injuries

  • High pushability

  • Short deflation rates

 

And with clinical support in:

  • A low crossing profile to cross the most complex injuries

  • An excellent design with the minimum amount of metal required to sustain the vessel

  • An homogeneous coverage of the arterial wall

High crossability

The low profile design allows the crossing of complex injuries.

High crossability

Lower restenosis

Restorer is designed to minimize the potential risk of restenosis thanks to a technologically innovative manufacturing process.

  • Optimized metal content while keeping an outsanding radial force
  • Ultrasmooth electropolished surface

Homogeneous treatment

The unique design of restorer provides a better adaptability to the vessel and an homogeneous coverage of the artery wall.

Stent material

CoCr L605

Wall thickness

125 to 150 micras

% Recoil

<6%

Foreshortening %

<3%

Vessel conformity

High

Nominal pressure

10 / 12 atm

Rated burst pressure

16 atm (8mm stents) / 14 atm (9-10mm stents)

Balloon

Semicompliant

Balloon crossing profile

 

DIÁMETRO PULGADAS=MM=FRENCH

 

Radiopaque markers

2 metallic marks at both sides of the stent

Delivery system dimensions

 

 

Introducer compatibility

 

 

Deflating rates

<30 s

References

All tests performed according to ISO 10555 and UNE EN 10993




 
heart